- Electrolux Air O Chill User Manual Free
- Electrolux Air O Chill User Manual Youtube
- Electrolux Air-o-chill Manual Pdf
- Electrolux Air O Chill User Manual 2017
- Electrolux Air-o-chill Service Manual
Air-o-convect with high resolution touch screen control, electric, 10x1/1GN, 2 cooking modes (manual, recipe program), air-o-clean functions - Norway, Estonia air-o-flow: fresh air from the outside is directed to the bi-functional fan, becomes pre-heated and then pushed into the cooking chamber to guarantee an even cooking process. View and Download Electrolux Air-O-Chill 726784 brochure & specs online. Blast Chillers 180 kg. Air-O-Chill 726784 Chiller pdf manual download. Also for: 726858, 726857, Aoc2028crd, Aoc2028crt, Aocp2028cr, 20 gn 2/1. Electrolux air-o-chill. Blast Chillers 70 kg - 10 GN 2/1. INSTALLATION. No water connections required. Waste water can be plumbed into drain, but can also be collected in an optional waste container.
Electrolux air-o-chill
Blast Chiller/Freezers 50-50kg
Internet: http://www.electrolux.com/foodservice
HDBB020
2012-07-26
Subject to change without notice
WATER REMOTE UNIT FOR C/FREEZER LW 50KG
880033
TROLLEY FOR SLIDE-IN RACK 6&10X1/1GN
922004
922004
TRAY RACK+WHEELS 8X1/1GN, 80MM PITCH
922009
922009
TRAY RACK+WHEELS 10X1/1GN, 65MM PITCH
922006
922006
SLIDE-IN RACK SUPP.10 1/1 BC+BCF 50KG-LW
881028
881028
SET OF 5 S/S RUNNERS-6&10 GN 1/1 BCF LW
880087
880087
RILSAN COATED GRID
881061
881061
REMOTE PRINTER HACCP BASIC ELECR.CONTR
881532
881532
PASTRY GRID(RILSAN)600X400MM-B/CHILLERS
880294
880294
PASTRY 8X(400X600)RACK+WHLS-80MM,10X1/1
922066
922066
PAIR OF 1/1 GN AISI 304 S/S GRIDS
921101
921101
KIT HACCP ADVANCED CONNECT. BCF LW+CW
880183
880183
KIT 4 WHEELS FOR BLAST C/FREEZERS
880111
BANQUET RACK-30PLATES-65MM PITCH-10GN1/1
922015
922015
AIR REMOTE UNIT FOR C/FREEZER LW 50KG
880030
3-POINT-SENSOR PROBE-BC/BCF LW&CW
Electrolux Air O Chill User Manual Free
880212
880212
3 SINGLE-SENSOR PROBES-BL.C/FREEZERS LW
880215
880215
2 SINGLE-SENSOR PROBES-BL.C/FREEZERS LW
880214
880214
1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW
880213
880213
ACCESSORIES
SET OF 5 S/S RUNNERS-6&10 GN 1/1 BCF LW
2
2
3-POINT-SENSOR PROBE-BC/BCF LW&CW
1
1
INCLUDED ACCESSORIES
installed-electric
4.26
0.42
Power - kW
at evaporation temperature - °C
-30
-10
Refrigerant power
Refrigeration power - W
2540
7150
Refrigerant quantity - g.
4500
Refrigerant type
R404a
R404a
Compressor power - HP
2.9
;
N° of positions/pitch, mm
36, 20
36, 20
Max load capacity - trays h 65 mm - n°
10
10

Trays type
600x400; GN 1/1; Ice Cream
600x400; GN 1/1; Ice Cream
Door hinges
Left
Left
height
1730
1730
depth/with open doors
1007, 1379
1007, 1478.5
width
895
895
External dimensions - mm
Thermometers
Digital
Digital
Thermostat
Electronic
Electronic
Cooling unit
Built-In
Remote

Gross capacity (D.I.N. 8952) - l.
560
560
UK Guide lines - chilling / freezing
50, 50
50, 50
NF Regulations - chilling / freezing
36, 36
36, 36
Productivity per cycle - kg.
Type
Blast freezer - 50 kg
Blast freezer - 50 kg
TECHNICAL DATA
AOFPS101C
726305
AOFPS101CR
726307
PERFORMANCE
•
Blast Chilling cycle: 50 kg from
+90°C up to + 3°C in less than 90
minutes.
•
Blast Freezing cycle: 50 kg from
90ºC up to -18 ºC in less than four
hours.
•
Multi-purpose internal structure is
suitable for 10 grids GN 1/1 (36
positions available with 20 mm pitch)
10 grids or trays 600 x 400 mm (36
positions availabe with 20 mm pitch)
or 18 ice-cream basins of 5 kg each
(h 125 x 165 x 360).
•
Chilling and freezing times can vary
according to food quantity, density,
moisture contents and type of
containers. Chilling capacity
according to NF* regulations is 36 kg.
CONSTRUCTION
•
Internal and external finishing in
304 AISI stainless steel and back
panel in stainless steel.
•
High density polyurethane
insulation, 60 mm thickness, HCFC
free.
•
Environmentally friendly: R404a as
refrigerant fluid.
•
Developed and produced in ISO
9001 and ISO 14001 certified factory.
•
Inner cell with fully rounded corners.
•
Door equipped with removable
magnetic gasket with hygienic design.
•
All motors and fan waterproof
protected IP23.
•
Evaporator with anti rust protection.
•
Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
•
Automatic heated door frame.
•
Hot gas defrosting system.
•
Solenoid valves.
•
1 thermostatic expansion valve.
•
Feet 150 mm high.
•
Stand alone printer as optional, built
in on request.
•
PC connection on request, gate RS
485.
INSTALLATION
•
No water connections required.
•
Waste can be plumbed into drain,
but can also be collected in optional
waste container.
*NF HYGIENE ALIMENTAIRE
certifying authority : AFAQ AFNOR
CERTIFICATION. Address:11, Avenue
Francis de Pressense - 93571
Saint-Denis La Plaine Cedex - France.
Conformity with regulation NF031.
Certified guarantees: fitness for cleaning,
thermal performance.
Installation diagram:
EQ - Equipotential screw
EH - HACCP
TCA - Technical connection area
RO - Refrigerant outlet
Page 2: Evaporator with antirust protection, Automatic heated door frame, Hot gas defrosting system, Solenoid valves, 1 thermostatic expansion valve, Feet 150 mm high, No water connections required
Electrolux air-o-chill
Blast Chillers 50 kg - 10 GN 1/1
Internet: http://www.electrolux.com/foodservice
HDAB020
2009-10-06
Subject to change without notice
WATER REMOTE UNIT BLAST CHILLER LW 50KG
880032
TROLLEY FOR SLIDE-IN RACK 6&10X1/1GN
922004
922004
TRAY RACK+WHEELS 8X1/1GN, 80MM PITCH
922009
922009
TRAY RACK+WHEELS 10X1/1GN, 65MM PITCH
922006
922006
THERMAL COVER FOR 10X1/1GN
922013
922013
SLIDE-IN RACK SUPP.10 1/1 BC+BCF 50KG-LW
881028
881028
RILSAN COATED GRID
881061
881061
PRINTER FOR HACCP BASIC VERSION
881532
881532
PASTRY(400X600)RACK+WHEELS-80MM,10 1/1LW
Electrolux Air O Chill User Manual Youtube
922066
922066
PAIR OF 1/1 GN AISI 304 S/S GRIDS
921101
921101
KIT HACCP EKIS
922166
922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW
880183
880183
KIT 4 WHEELS FOR BLAST C/FREEZERS
880111
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF
880269
880269
BANQUET RACK-30PLATES-65MM PITCH-10GN1/1
922015
922015
BANQUET RACK-23PLATES-85MM PITCH-10GN1/1
922071
922071
AIR REMOTE UNIT F.BLAST CHILLER LW 50KG
880029
2 SINGLE SENSOR PROBES CHILLER+C/FREEZER
880096
880096
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER
880089
880089
ACCESSORIES
TRAY RACK FOR BC+BCF LW 50KG 10 GN1/1
1
1
3-SENSOR PROBE FOR CHILLER+C/FREEZER
1
1
INCLUDED ACCESSORIES
installed-electric
3.472
0.45
Power - kW
at evaporation temperature - °C
-5
-10
Refrigerant power
Refrigeration power - W
7340
5950
Refrigerant quantity - g.
4415
Refrigerant type
R404a
R404a
N° defrost in 24 hrs.
6
6
Compressor power - HP
2; 8
Max load capacity - trays h 65 mm - n°
10
10
Trays type
GN 1/1; 600x400
GN 1/1; 600x400
Door hinges
Left
Left
N° and type of door
1
1
height
1730
1730
depth/with open doors
995
995
width
895
895
External dimensions - mm
Thermometers
Digital
Digital
Thermostat
Electronic
Electronic
Cooling unit
Built-In
Remote
Gross capacity (D.I.N. 8952) - l.
560
UK Guide lines - chilling / freezing
50
50
NF Regulations - chilling / freezing
Electrolux Air-o-chill Manual Pdf
36
36
Productivity per cycle - kg.
Electrolux Air O Chill User Manual 2017
Type
Blast Chiller - 50 kg
Blast Chiller - 50 kg
TECHNICAL DATA
AOCP101C
726693
AOCP101CR
726694
CONSTRUCTION
•
Internal and external finishing in 304
AISI stainless steel and back panel in
stainless steel.
•
High density polyurethane
insulation, 60 mm tickness, HCFC
free.
•
Environmentally friendly: R404a as
refrigerant fluid.
•
Developed and produced in ISO
9001 and ISO 14001 certified factory.
•
Inner cell with fully rounded corners.
•
Door equipped with removable
magnetic gasket with hygienic design.
•
Motors and fan waterproof
protected IP20.
•
Evaporator with antirust protection.
•
Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
•
Automatic heated door frame.
•
Electrolux Air-o-chill Service Manual
Hot gas defrosting system.
•
Solenoid valves.
•
1 thermostatic expansion valve.
•
Feet 150 mm high.
•
Stand alone printer as optional, built
in on request.
•
PC connection on request, gate RS
485.
INSTALLATION
•
No water connections required.
•
Waste water can be plumbed into
drain, but can also be collected in an
optional waste container.
*NF HYGIENE ALIMENTAIRE
certifying authority : AFAQ AFNOR
CERTIFICATION. Adress:11, Avenue
Francis de Pressense - 93571
Saint-Denis La Plaine Cedex - France.
Conformity with regulation NF031.
Certified guarantees: fitness for
cleaning, thermal performance.
Installation diagram:
C - Water drain
I - Electrical connection
Y - Connection for appliance lifting
L - Remote electrical connection
N - Cooling water inlet
O - Cooling water outlet