Electrolux Air O Chill User Manual

Advertising

Air-o-convect with high resolution touch screen control, electric, 10x1/1GN, 2 cooking modes (manual, recipe program), air-o-clean functions - Norway, Estonia air-o-flow: fresh air from the outside is directed to the bi-functional fan, becomes pre-heated and then pushed into the cooking chamber to guarantee an even cooking process. View and Download Electrolux Air-O-Chill 726784 brochure & specs online. Blast Chillers 180 kg. Air-O-Chill 726784 Chiller pdf manual download. Also for: 726858, 726857, Aoc2028crd, Aoc2028crt, Aocp2028cr, 20 gn 2/1. Electrolux air-o-chill. Blast Chillers 70 kg - 10 GN 2/1. INSTALLATION. No water connections required. Waste water can be plumbed into drain, but can also be collected in an optional waste container.

Electrolux air-o-chill

Blast Chiller/Freezers 50-50kg

Internet: http://www.electrolux.com/foodservice

HDBB020

2012-07-26

Subject to change without notice

WATER REMOTE UNIT FOR C/FREEZER LW 50KG

880033

TROLLEY FOR SLIDE-IN RACK 6&10X1/1GN

922004

922004

TRAY RACK+WHEELS 8X1/1GN, 80MM PITCH

922009

922009

TRAY RACK+WHEELS 10X1/1GN, 65MM PITCH

922006

922006

SLIDE-IN RACK SUPP.10 1/1 BC+BCF 50KG-LW

881028

881028

SET OF 5 S/S RUNNERS-6&10 GN 1/1 BCF LW

880087

880087

RILSAN COATED GRID

881061

881061

REMOTE PRINTER HACCP BASIC ELECR.CONTR

881532

881532

PASTRY GRID(RILSAN)600X400MM-B/CHILLERS

880294

880294

PASTRY 8X(400X600)RACK+WHLS-80MM,10X1/1

922066

922066

PAIR OF 1/1 GN AISI 304 S/S GRIDS

921101

921101

KIT HACCP ADVANCED CONNECT. BCF LW+CW

880183

880183

KIT 4 WHEELS FOR BLAST C/FREEZERS

880111

BANQUET RACK-30PLATES-65MM PITCH-10GN1/1

922015

922015

AIR REMOTE UNIT FOR C/FREEZER LW 50KG

880030

3-POINT-SENSOR PROBE-BC/BCF LW&CW

Electrolux Air O Chill User Manual Free

880212

880212

3 SINGLE-SENSOR PROBES-BL.C/FREEZERS LW

880215

880215

2 SINGLE-SENSOR PROBES-BL.C/FREEZERS LW

880214

880214

1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW

880213

880213

ACCESSORIES

SET OF 5 S/S RUNNERS-6&10 GN 1/1 BCF LW

2

2

3-POINT-SENSOR PROBE-BC/BCF LW&CW

1

1

INCLUDED ACCESSORIES

installed-electric

4.26

0.42

Power - kW

at evaporation temperature - °C

-30

-10

Refrigerant power

Refrigeration power - W

2540

7150

Refrigerant quantity - g.

4500

Refrigerant type

R404a

R404a

Compressor power - HP

2.9

;

N° of positions/pitch, mm

36, 20

36, 20

Max load capacity - trays h 65 mm - n°

10

10

Electrolux Air O Chill User Manual

Trays type

600x400; GN 1/1; Ice Cream

600x400; GN 1/1; Ice Cream

Door hinges

Left

Left

height

1730

1730

depth/with open doors

1007, 1379

1007, 1478.5

width

895

895

External dimensions - mm

Thermometers

Digital

Digital

Thermostat

Electronic

Electronic

Cooling unit

Built-In

Remote

Electrolux Air O Chill User Manual

Gross capacity (D.I.N. 8952) - l.

560

560

UK Guide lines - chilling / freezing

50, 50

50, 50

NF Regulations - chilling / freezing

36, 36

36, 36

Productivity per cycle - kg.

Type

Blast freezer - 50 kg

Blast freezer - 50 kg

TECHNICAL DATA

AOFPS101C

726305

AOFPS101CR

726307


PERFORMANCE

Blast Chilling cycle: 50 kg from

+90°C up to + 3°C in less than 90
minutes.

Blast Freezing cycle: 50 kg from

90ºC up to -18 ºC in less than four
hours.

Multi-purpose internal structure is

suitable for 10 grids GN 1/1 (36
positions available with 20 mm pitch)
10 grids or trays 600 x 400 mm (36
positions availabe with 20 mm pitch)
or 18 ice-cream basins of 5 kg each
(h 125 x 165 x 360).

Chilling and freezing times can vary

according to food quantity, density,
moisture contents and type of
containers. Chilling capacity
according to NF* regulations is 36 kg.
CONSTRUCTION

Internal and external finishing in

304 AISI stainless steel and back

panel in stainless steel.

High density polyurethane

insulation, 60 mm thickness, HCFC
free.

Environmentally friendly: R404a as

refrigerant fluid.

Developed and produced in ISO

9001 and ISO 14001 certified factory.

Inner cell with fully rounded corners.

Door equipped with removable

magnetic gasket with hygienic design.

All motors and fan waterproof

protected IP23.

Evaporator with anti rust protection.

Ventilator (fan) swinging hinged

panel for access to the evaporator for
cleaning.

Automatic heated door frame.

Hot gas defrosting system.

Solenoid valves.

1 thermostatic expansion valve.

Feet 150 mm high.

Stand alone printer as optional, built

in on request.

PC connection on request, gate RS

485.
INSTALLATION

No water connections required.

Waste can be plumbed into drain,

but can also be collected in optional
waste container.

*NF HYGIENE ALIMENTAIRE

certifying authority : AFAQ AFNOR
CERTIFICATION. Address:11, Avenue
Francis de Pressense - 93571
Saint-Denis La Plaine Cedex - France.
Conformity with regulation NF031.
Certified guarantees: fitness for cleaning,
thermal performance.
Installation diagram:
EQ - Equipotential screw
EH - HACCP
TCA - Technical connection area
RO - Refrigerant outlet

Advertising
This manual is related to the following products:
Popular Brands
Popular manuals

Page 2: Evaporator with antirust protection, Automatic heated door frame, Hot gas defrosting system, Solenoid valves, 1 thermostatic expansion valve, Feet 150 mm high, No water connections required

Advertising

Electrolux air-o-chill

Blast Chillers 50 kg - 10 GN 1/1

Internet: http://www.electrolux.com/foodservice

HDAB020

2009-10-06

Subject to change without notice

WATER REMOTE UNIT BLAST CHILLER LW 50KG

880032

TROLLEY FOR SLIDE-IN RACK 6&10X1/1GN

922004

922004

TRAY RACK+WHEELS 8X1/1GN, 80MM PITCH

922009

922009

TRAY RACK+WHEELS 10X1/1GN, 65MM PITCH

922006

922006

THERMAL COVER FOR 10X1/1GN

922013

922013

SLIDE-IN RACK SUPP.10 1/1 BC+BCF 50KG-LW

881028

881028

RILSAN COATED GRID

881061

881061

PRINTER FOR HACCP BASIC VERSION

881532

881532

PASTRY(400X600)RACK+WHEELS-80MM,10 1/1LW

Electrolux Air O Chill User Manual Youtube

922066

922066

PAIR OF 1/1 GN AISI 304 S/S GRIDS

921101

921101

KIT HACCP EKIS

922166

922166

KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW

880183

880183

KIT 4 WHEELS FOR BLAST C/FREEZERS

880111

KIT 3 SINGLE SENSOR PROBES FOR BC/BCF

880269

880269

BANQUET RACK-30PLATES-65MM PITCH-10GN1/1

922015

922015

BANQUET RACK-23PLATES-85MM PITCH-10GN1/1

922071

922071

AIR REMOTE UNIT F.BLAST CHILLER LW 50KG

880029

2 SINGLE SENSOR PROBES CHILLER+C/FREEZER

880096

880096

1 SINGLE SENSOR PROBE CHILLER+C/FREEZER

880089

880089

ACCESSORIES

TRAY RACK FOR BC+BCF LW 50KG 10 GN1/1

1

1

3-SENSOR PROBE FOR CHILLER+C/FREEZER

1

1

INCLUDED ACCESSORIES

installed-electric

3.472

0.45

Power - kW

at evaporation temperature - °C

-5

-10

Refrigerant power

Refrigeration power - W

7340

5950

Refrigerant quantity - g.

4415

Refrigerant type

R404a

R404a

N° defrost in 24 hrs.

6

6

Compressor power - HP

2; 8

Max load capacity - trays h 65 mm - n°

10

10

Trays type

GN 1/1; 600x400

GN 1/1; 600x400

Door hinges

Left

Left

N° and type of door

1

1

height

1730

1730

depth/with open doors

995

995

width

895

895

External dimensions - mm

Thermometers

Digital

Digital

Thermostat

Electronic

Electronic

Cooling unit

Built-In

Remote

Gross capacity (D.I.N. 8952) - l.

560

UK Guide lines - chilling / freezing

50

50

NF Regulations - chilling / freezing

Electrolux Air-o-chill Manual Pdf

36

36

Productivity per cycle - kg.

Electrolux Air O Chill User Manual 2017

Type

Blast Chiller - 50 kg

Blast Chiller - 50 kg

TECHNICAL DATA

AOCP101C

726693

AOCP101CR

726694

CONSTRUCTION

Internal and external finishing in 304

AISI stainless steel and back panel in
stainless steel.

High density polyurethane

insulation, 60 mm tickness, HCFC
free.

Environmentally friendly: R404a as

refrigerant fluid.

Developed and produced in ISO

9001 and ISO 14001 certified factory.

Inner cell with fully rounded corners.

Door equipped with removable

magnetic gasket with hygienic design.

Motors and fan waterproof

protected IP20.

Evaporator with antirust protection.

Ventilator (fan) swinging hinged

panel for access to the evaporator for
cleaning.

Automatic heated door frame.

Electrolux Air-o-chill Service Manual

Hot gas defrosting system.

Solenoid valves.

1 thermostatic expansion valve.

Feet 150 mm high.

Stand alone printer as optional, built

in on request.

PC connection on request, gate RS

485.
INSTALLATION

No water connections required.

Waste water can be plumbed into

drain, but can also be collected in an
optional waste container.

*NF HYGIENE ALIMENTAIRE
certifying authority : AFAQ AFNOR
CERTIFICATION. Adress:11, Avenue
Francis de Pressense - 93571
Saint-Denis La Plaine Cedex - France.
Conformity with regulation NF031.
Certified guarantees: fitness for
cleaning, thermal performance.
Installation diagram:
C - Water drain
I - Electrical connection
Y - Connection for appliance lifting
L - Remote electrical connection
N - Cooling water inlet
O - Cooling water outlet

Advertising
This manual is related to the following products:
Popular Brands
Popular manuals